XTV12850 battery is specially designed for extreme temperatures (-20 to 50 ℃). Innovative Valve egulated Lead-Acid (VRLA) technology enables a 12-year design life in standby use, or more than 260 cycles at 100% discharge.
CSB Batteries can be stored for more than 6 months at 25°C (77°F) Please charge batteries before using. For higher temperatures the time interval will be shorter.
Terminal
I2-Thread lead alloy recessed terminal to accept M6/M8 bolt
Container Material
PP (UL 94-V0/File E50955)*Flammability resistance of (UL 94-HB/File E216959) can be available upon request.
Dimensiones
Caracteristicas de Corriente de Descarga Constante Unidad:Amperios (25°C,77°F)
Tension Final/Tiempo
5MIN
10MIN
15MIN
30MIN
1HR
2HR
3HR
4HR
5HR
8HR
10HR
20HR
1.60V
323.00
224.00
170.00
103.00
62.00
36.80
25.30
19.40
16.10
10.70
8.90
4.64
1.67V
286.00
209.00
163.00
101.00
60.60
36.00
25.10
19.30
15.90
10.60
8.80
4.61
1.70V
266.00
200.00
159.00
99.40
59.90
35.70
24.80
19.10
15.80
10.50
8.78
4.59
1.75V
236.00
185.00
151.00
95.60
58.30
34.60
24.10
18.70
15.60
10.30
8.58
4.54
1.80V
215.00
166.00
139.00
90.10
56.10
33.20
23.60
18.50
15.30
10.20
8.50
4.46
1.85V
178.00
148.00
121.00
82.70
52.30
31.00
22.40
17.50
14.50
9.85
8.10
4.28
Caracteristicas de Corriente de Descarga Constante Unidad:Watts (25°C,77°F)